MC9190 with ADP9000 and DW tethered to a scanner

P Pavel Bodjanac 3 years 5 months ago
0 0 0

Hi Team, I'm not sure how much experience you all have with using an ADP-9000 to tether a scanner to an MC9190 but my customer is looking to do this. I was able to get this working and wanted to share with you all in case you need it in the future. Equipment:

MC9190 with Datawedge

ADP9000-110R

Sinbon Cable A9110525-01

LS and DS scanners

 

-          On LS scanners scan the default setting barcode and then whatever barcode formatting setting you need additionally

-          On DS scanner first scan the default setting barcode, then scan “Do Not Check For Receive Errors” setting barcode, and lastly whatever barcode formatting setting you need additionally

-          On the MC9190, configure Datawedge …

 

                Reset the settings for DataWedge to the default

                                DataWedge Advanced Configuration

                                Settings

                                Restore Defaults

                                OK

 

               Setting Input Source

                               DataWedge Advanced Configuration

  Profiles

                                Profile0

                                Input

                                Serial

                                COM1:

                                Ensure “Enabled” is checked

                                Port Settings

                                Ensure the Port settings are 9600/8/1/none

                               

                Tap “Home” in the upper right to save changes.

 

                Route Configuration

  DataWedge Advanced Configuration

                                Profiles

                                Profile0

                                Routes

                                Add New

                                Enter a name for the route or leave it as the default (“Route1”)

                                Save

                                Input

                                Plugin

                                Serial

               

                                Tap “Home” in the upper right to save changes.

 

-          Next put the system together, start datawedge, it should turn on the scanner and allow you to scan data into the open field

 

I tested the ADP9000-110R with LS3408-ER,LS3408-FZ, LS2208, and DS3508-SR … and all worked well

 

I also tried the ADP9000-100R and while it worked with the LS2208, LS3408-FZ, and DS3508-SR, it did not work with the LS3408-ER. I would suggest our customers not use the ADP-9000-100R but rather use the ADP9000-110R.

CONTACT